Test 1 Results
Rate of Neutralization of diluted acidic plating solution from initial pH of 1.55
Sampling Time (minutes) pH Temperature (0C) Weight of limestone
0 1.55 31 11.2 kg
(Test 1a)
10 1.92 31
20 2.02 31
30 2.39 31
40 2.57 31
50 4.87 31 22.4 kg
(Test 1b)
60 4.88 31
Test 2 Results
Rate of Neutralization of diluted acidic plating solution from initial pH of 2.30
Sampling Time (Minutes) pH Temperature (0C) Weight of limestone
0 2.30 31

30.0 kg

(Test 2)

10 4.42 31
20 4.88 31
26 4.97 31
30 4.97 31
Summary of neutralization rate and pH change

Test

pH range

Rate of Neutralization per minute pH change per kg limestone
1a 1.55 – 2.57 0.06 0.09
1b 2.57 – 4.88 0.12 0.10
2 2.30 – 4.97 0.08 0.09
Back to top